Near-Miss Reporting System - Report Number 08-0000115
| ... I ran up the pressure on the engine to 400psi and walked around to the other side of the truck and began closing the hose testing gate. ... www.firefighternearmiss.com/googlemini2/h08-0000115.html - 3k - 2010-09-02 - Cached |
Near-Miss Reporting System - Report Number 10-0000116
| ... Our department utilizes a contract company to perform annual hose testing and the contract company removes and repacks all hose. ... www.firefighternearmiss.com/googlemini2/h10-0000116.html - 5k - 2010-09-02 - Cached |
Near-Miss Reporting System - Report Number 09-0000433
| Report Number: 09-0000433 Report Date: 04/22/2009 Event Description. Our crew was performing annual hose testing on a concrete street in an industrial park. ... www.firefighternearmiss.com/googlemini2/h09-0000433.html - 2k - 2010-09-02 - Cached |
Near-Miss Reporting System - Report Number 09-0000478
| ... all. The broken piece was about fifteen feet from the coupler and this section was attached directly to the hose testing machine. ... www.firefighternearmiss.com/googlemini2/h09-0000478.html - 3k - 2010-09-02 - Cached |
Near-Miss Reporting System - Report Number 06-0000565
| ... Event Description. During annual hose testing, a 4” section of hose failed next to the pump panel where the a firefighter was standing. ... www.firefighternearmiss.com/googlemini2/h06-0000565.html - 2k - 2010-09-02 - Cached |
Near-Miss Reporting System - Report Number 05-0000556
| ... We had been doing hose testing all morning, laying out and rolling up 100 foot lengths of 5-inch supply line, on blacktop, in 95 degree August heat. ... www.firefighternearmiss.com/googlemini2/h05-0000556.html - 4k - 2010-09-02 - Cached |
Near-Miss Reporting System - Report Number 05-0000474
| ... Event Description. During annual hose testing while reloading hose, the inside liner of 1 3/4 attack line was found to be bunched up against the male coupling. ... www.firefighternearmiss.com/googlemini2/h05-0000474.html - 2k - 2010-09-02 - Cached |
Near-Miss Reporting System - Report Number 10-0001019
| ... Our company was finishing hose testing and started to bleed pressure from the hose test machine. ... Prevention: Proper training and procedures on hose testing. ... www.firefighternearmiss.com/googlemini2/h10-0001019.html - 2k - 2010-09-02 - Cached |
Near-Miss Reporting System - Report Number 09-0000856
| Report Number: 09-0000856 Report Date: 08/28/2009 Event Description. Member was participating in annual hose testing when tester tripped the GFCI plug. ... www.firefighternearmiss.com/googlemini2/h09-0000856.html - 2k - 2010-09-02 - Cached |
Near-Miss Reporting System - Report Number 09-0000730
| ... During the testing, the hose tester tilted over. Gas started leaking from the fuel tank. ... Use recommended hose testing procedures as outlined in NFPA 1961. ... www.firefighternearmiss.com/googlemini2/h09-0000730.html - 2k - 2010-09-02 - Cached |